On the Equivalent Sources and Geometric Factor Calculation for a Circular Detection Case

Tony Jesus Viloria Avila, Luis Montiel, Laszlo Sajó Bohus, Daniel Palacios

Research output: Contribution to journalArticle

Abstract

In all absolute measurements of the intensity of the radioactive materials and calibration of the detectors, it is essential the knowledge of the geometric efficiency. This work describes how to obtain the sources with different geometries and equal geometric efficiency (equivalent sources for geometric factor), corresponding to a linear, circumferential and circular homogeneous sources parallel to a circular detector. It is estimated the geometric factor of them by the Monte Carlo method. The results are compared with the published in the literature, thus confirming the validity of this method.
Translated title of the contributionSobre las Fuentes Equivalentes y el Cálculo del Factor Geométrico para un Caso de Detección Circular
Original languageEnglish (US)
Pages (from-to)1-18
Number of pages18
JournalJournal of Nuclear Physics, Material Sciences, Radiation and Applications
Volume4
Issue number4
DOIs
StatePublished - 8 Aug 2016

Keywords

  • Equivalent source
  • Geometric factor
  • Monte carlo method

CACES Knowledge Areas

  • 145A Mathematics

Fingerprint

Dive into the research topics of 'On the Equivalent Sources and Geometric Factor Calculation for a Circular Detection Case'. Together they form a unique fingerprint.

Cite this