Numerical Comparison Using CFD of R134a and R600a Condensation in Helical and Spiral Exchangers

Fernando Toapanta Ramos, Tito Hidalgo, Jefferson Parra, William Quitiaquez

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

The objective of this research document is to analyze numerically through the ANSYS software using the CFD (Computational Fluid Dynamics) tool, to determine the behavior of refrigerants R134a and R600a in the condensation process that is generated in the helical and spiral exchangers. For the investigation, fluid mechanics parameters were adjusted as thermal, for this the work equations were obtained through different texts and investigations and initial parameters were established for the work fluids and characteristics of the pipe. In addition, in the specific analysis of condensation, the Fluent tool of the ANSYS software was used, defining the mesh and applying the Euler volume fraction model. It is evident that the best results obtained in the simulations correspond to cases E and M with ambient temperatures of 20 ℃ and 17 ℃ at an inlet velocity of 1.2 m/s with geometry of the helical-type exchanger for refrigerants. R134a and R600a, respectively. Where outlet temperatures of 296.025 K and 295.622 K are obtained, in addition to visualizing that in all the study cases the condensation phenomenon occurs and the temperature at the outlet of the coil register values like those obtained numerically.

Original languageEnglish
Title of host publicationSmart Technologies, Systems and Applications - 3rd International Conference, SmartTech-IC 2022, Revised Selected Papers
EditorsFabián R. Narváez, Fernando Urgilés, Juan Pablo Salgado-Guerrero, Teodiano Freire Bastos-Filho
PublisherSpringer Science and Business Media Deutschland GmbH
Pages425-438
Number of pages14
ISBN (Print)9783031322129
DOIs
StatePublished - 2023
Event3rd International Conference on Smart Technologies, Systems and Applications, SmartTech-IC 2022 - Cuenca, Ecuador
Duration: 16 Nov 202218 Nov 2022

Publication series

NameCommunications in Computer and Information Science
Volume1705 CCIS
ISSN (Print)1865-0929
ISSN (Electronic)1865-0937

Conference

Conference3rd International Conference on Smart Technologies, Systems and Applications, SmartTech-IC 2022
Country/TerritoryEcuador
CityCuenca
Period16/11/2218/11/22

Bibliographical note

Funding Information:
The authors of this research thank the mechanical engineering career of the Salesian Polytechnic University, the Research Group on Renewable Energies and Mechanical Implementation of SMEs GIERIMP, Industrial Production Research Group (GIPI) and the Branch ASHRAE UPS-QUITO.

Publisher Copyright:
© 2023, The Author(s), under exclusive license to Springer Nature Switzerland AG.

Keywords

  • ANSYS
  • CFD
  • condenser
  • helical
  • R134a
  • R600a
  • refrigerant
  • spiral

Fingerprint