Tremors quantification in Parkinson patients using smartwatches

Título traducido de la contribución: Cuantificación de temblores en enfermos de Parkinson con smartwatches

R. Contreras, M. Huerta, G. Sagbay, C. Llumiguano, M. Bravo, A. Bermeo, R. Clotet, A. Soto

Producción científica: Capítulo del libro/informe/acta de congresoContribución de conferenciarevisión exhaustiva

15 Citas (Scopus)

Resumen

Parkinson's disease is a neurological disorder that affects about 1% of people over 60 years. The complexity of the disease difficult to carry out objective medical assessments of the level of tremors. This article presents a system which uses the accelerometer and gyroscope sensors in smartwatches to quantify the tremors in patients with Parkinson's disease. The system is based on a Wireless Body Area Network composed by multiple sensor nodes (Android Wears) and one sink node (Android Smartphone). The system integrates four processes: User authentication, placement of sensors on the body, movement sensing and data uploading. The system was evaluated in 12 patients with PD (five males and seven females) while they were doing several activities, but in this article we only analyses when the patients were seated at rest. The patients had an average disease duration of 6.25 years, an average age of 66.33 years and a range of 5186 years. The tremor magnitudes were presented in the form of linear acceleration and angular velocity in the time domain. The results indicate that these variables can determine Parkinson's disease evolution in a patient diagnosed with stage 3 and 4.

Título traducido de la contribuciónCuantificación de temblores en enfermos de Parkinson con smartwatches
Idioma originalInglés
Título de la publicación alojada2016 IEEE Ecuador Technical Chapters Meeting, ETCM 2016
EditorialInstitute of Electrical and Electronics Engineers Inc.
ISBN (versión digital)9781509016297
DOI
EstadoPublicada - 21 nov. 2016
Evento2016 IEEE Ecuador Technical Chapters Meeting, ETCM 2016 - Quito, Ecuador
Duración: 12 oct. 201614 oct. 2016

Serie de la publicación

Nombre2016 IEEE Ecuador Technical Chapters Meeting, ETCM 2016

Conferencia

Conferencia2016 IEEE Ecuador Technical Chapters Meeting, ETCM 2016
Título abreviadoETCM 2016
País/TerritorioEcuador
CiudadQuito
Período12/10/1614/10/16

Nota bibliográfica

Publisher Copyright:
© 2016 IEEE.

Huella

Profundice en los temas de investigación de 'Cuantificación de temblores en enfermos de Parkinson con smartwatches'. En conjunto forman una huella única.

Citar esto