Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Errors in the measurement systems with the inclusion of single-phase loads at 220V in three-phase distribution networks

  • M. A. Toledo
  • , C. M. Alvarez
  • , D. X. Morales
  • , C. E. Arias

Producción científica: Capítulo del libro/informe/acta de congresoContribución de conferenciarevisión exhaustiva

Resumen

This research analyzes the problems presented by the measurement systems in one Phase three wires electrical distribution networks when single-phase loads are connected to 220V and proposes to replace the equation to eliminate the error that occurs in the energy meter. This case of study was given in Ecuador due to the massive inclusion of induction cookers through the change of the energy matrix promoted by the state since this account with more than 90 of hydroelectric energy to meet their electric demand.It is important to explain that this research does not include in the state of the art the problem and the solutions, because this novelty was presented promptly in Ecuador due to the technical conditions of the energy distribution system, at the voltage level versus the construction voltage of the single-phase loads that in the case of induction cookers were imported from countries that handle 220V single-phase voltages. This consequence does not present a choice, it is ethical for those responsible for the measurement systems of the Utility, to present a solution to the inconvenience of how it is developed in this investigation.

Idioma originalInglés
Título de la publicación alojadaIEEE CHILEAN Conference on Electrical, Electronics Engineering, Information and Communication Technologies, CHILECON 2019
EditorialInstitute of Electrical and Electronics Engineers Inc.
ISBN (versión digital)9781728131856
DOI
EstadoPublicada - nov. 2019
Publicado de forma externa
Evento2019 IEEE CHILEAN Conference on Electrical, Electronics Engineering, Information and Communication Technologies, CHILECON 2019 - Valparaiso, Chile
Duración: 13 nov. 201927 nov. 2019

Serie de la publicación

NombreIEEE CHILEAN Conference on Electrical, Electronics Engineering, Information and Communication Technologies, CHILECON 2019

Conferencia

Conferencia2019 IEEE CHILEAN Conference on Electrical, Electronics Engineering, Information and Communication Technologies, CHILECON 2019
País/TerritorioChile
CiudadValparaiso
Período13/11/1927/11/19

Nota bibliográfica

Publisher Copyright:
© 2019 IEEE.

Huella

Profundice en los temas de investigación de 'Errors in the measurement systems with the inclusion of single-phase loads at 220V in three-phase distribution networks'. En conjunto forman una huella única.

Citar esto