Abstract
The purpose of this document is to identify the best position of an acoustic emission sensor in a gearbox for fault detection. The acoustic emission sensor was located in the four side walls of the gearbox, where three signals were acquired in each position to be analyzed in the time domain by condition indicators and finally the best signals were analyzed in the frequency do-main by means of the gear step frequency. As a result, it was obtained that the sensor must be positioned in the shorter length lateral parts of the gearbox.
Translated title of the contribution | Methodology for the Location of the Acoustic Emission Sensor in a Gear Box |
---|---|
Original language | Spanish (Ecuador) |
Pages (from-to) | 32-42 |
Number of pages | 11 |
Journal | Ingenio Magno |
Volume | 9 |
Issue number | 9 |
State | Published - 27 Sep 2018 |
Keywords
- Acoustic emission
- Condition monitoring
- Frequency indicators
- Gear frequency
- Gearbox
CACES Knowledge Areas
- 727A Industrial and process design