Abstract
In this article the results of the simulation of the thermodynamic behavior of three domesticrefrigeration used in refrigerants, HFC-134a, HC-600a and HC-R290 is present, pure and mixed percentage, using as tools REFPROP analysis software and the Engineering Equations Solver (EES) software. The values of work input to the compressor, cooling capacity, the heat transferred to the capacitor and the coefficient of performance of the refrigeration system determined that the refrigerant mixture R134a / R600a in proportion 10/90, meets the best thermodynamicrequirements, maintaining an acceptable value of COP, pressure and temperature.
Translated title of the contribution | Analysis of the Behavior of Refrigerating R134a when Percentage Combined with Hydrocarbon Refrigerants R600a and R290 |
---|---|
Original language | Spanish (Ecuador) |
State | Published - 18 Apr 2016 |
Event | Tercer Congreso Internacional sobre Tecnologías Avanzadas de Mecatrónica, Diseño y Manufactura, AMDM 2016 - CO Duration: 13 Apr 2016 → 15 Apr 2016 https://www.uao.edu.co/ingenieria/congreso-sobre-tecnologias-avanzadas-de-mecatronica-diseno-y-manufactura/ |
Conference
Conference | Tercer Congreso Internacional sobre Tecnologías Avanzadas de Mecatrónica, Diseño y Manufactura, AMDM 2016 |
---|---|
Period | 13/04/16 → 15/04/16 |
Internet address |
Keywords
- Domestic
- Refrigerants
- Refrigeration
- Simulation
- Thermodynamic properties
CACES Knowledge Areas
- 317A Electricity and Energy